Home automation  > Home Automation  > Modules
Home Automations modules

Home automation modules are designed to action the various functions of the HOME SAPIENS system in such a way that they interact according to external conditions (temperature, light, humidity etc.) in order to optimize the level of perceived comfort in the home while at the same time reducing energy consumption to a minimum and providing excellent security. The various modules function independently of the terminals, and they can be utilized with traditional electrical systems to create home automation systems at a truly reasonable price.

 

 



Download






News

HOME SAPIENS WEB INTERFACE
Home automation at hand
The goal is saving
A guide to the energy efficiency of your building



Articles

Analog input and output modules

OH/AO4010-OUTPUTS MODULE 4 analogue outputs module type 0-10V with 4 related digital outputs and 4 digital inputs. Allows up to 4 analogue outputs type 0-10V to be controlled to which 4 power on/off relays are related. Allows the management of devices used with standard 0-10V inputs, for example solenoid valves with proportional open/close, generic dimmers and fan coils. The 4 logics, configurable through the programming tool, with which you can check the outputs, are: manual, linear (for example to control the opening of a solenoid valve that manages the discharge of water depending on the level of water inside a pool), in step (for example set 4 levels of opening of solenoid valve depending on 4 thresholds of temperature for the area), pursuit (for example, to maintain a constant temperature within an environment, configuring the system so that it manages the opening of solenoid valves, hot and cold depending on the outdoor temperature to allow that inside to seek the set point value). Can be installed, with or without terminal covers, to the wall using the DINguide provided or in containers provided with DIN guide (dimensions 6 DINunits).
OH/AI4-INPUTS MODULE 4 analogue inputs module 0-10V, 4-20mA type. Done on miniaturised container, it's able to acquire up to 4 analogue inputs type 0-1V, 0-10V, 0-20mA, 4-20mA, or pulse signals up to 25 kHz. Allows the home automation system to use analogue signals from wind, rain, light, humidity, and temperature sensors necessary for the implementation of checks for savings, comfort and security (example: it ensures the security closure of blinds depending on wind speed). Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DIN unit). The module should be installed as far as possible in the vicinity of the sensor.
OH/DI2230 DIMMER MODULE 2X300W Dimmer module with 2 300W channels each, 2 digital inputs and 2 analogue 0-10V inputs for interfacing with light sensors. Allows the dimming of 2 300W loads or of a 500W load to be controlled putting in parallel with the outputs. The two analogue inputs and the two digital inputs to locally connect the light and dusk probes to allow light management for an optimal environment. it permits, for example the light of a room to be adjusted according to external light and works according to a manual, linear, in step or sought logic. Can be installed, with or without terminal covers, to the wall using the DINguide provided or in containers provided with DINguide (dimensions 6 DIN units).
OH/AO1010-OUTPUT MODULE 1 channel dimmer control module. The OH/AO1010 is a device necessary to manage an analog output 0-10V, to which is also connected an ON/OFF relay. This module could manage devices controllable with standard 0-10V input such as solenoid valves, traditional dimmers, fancoils. The 0-10 output could be controlled with 4 different logics, through the programming software: MANUAL LOGIC: if the related input is activated for less than 1 second, the OUTPUT is controlled in STEP by STEP mode. If the related input is activated for more than 2 seconds, the OUTPUT is controlled with a periodic ramp (always growing), starting from the value of the input closing. When the input will be released it is kept the value previously reached. Finally if the related input is activated for a time between 1 and 2 seconds, the output is piloted to the maximum value (100%). LINEAR LOGIC: the 0-10V output simulates, in a linear way (using a scale factor), the evolution of a related analog input in the system. STEP LOGIC: the 0-10V output takes specific values which are associated to analog input thresholds or to digital input activations. FOLLOWING LOGIC: the output is set to follow an analog input value of the system. The OH/AO1010 module can be installed in electrical boxes with DIN guide (size: 1 DIN unit) and can be placed in a recessed box of 3 or more modules. NB: the module OH/AO1010 replaces the module NH/DIM and it is programmable in the same way as per the OH/AO4010 module.

Automation modules

Digital input and output modules

OH/4I-INPUTS/OUTPUTS MODULE Module 4 digital inputs and 4 outputs for the LED guiding with low voltage. Done on miniaturised container it is able to manage up to 4 inputs and is able to control 4 LEDs in low voltage (power between 1.5 and 3.5 V) in any colour. Individual LEDs can be combined by programming software with 4 digital outputs of the system to get a visual feedback of their power on/off status. Also lets you select the mode of LED operation between always on, not inverting (on if relay closed), interveting (on if relay open). Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DINunit).
OH/RI4416-RELAY MODULE 4 digital outputs module with 16A with exchange and manual rearm and 4 digital inputs. Manages up to 4 power relays with 16Awith the opportunity to rearm the load manually in the case of faults. To this end there are in 4 levers accessible from the outside that allow the manual driving of the individual relays either in the NO (normally open) position or NC (normally closed) also in the event of lack of power to the module. Can be installed, with or without terminal covers, to the wall using the DINguide provided or in containers provided with DINguide (dimensions 6 DINunits)
OH/6I-INPUTS MODULE 6 digital inputs module. Done on miniaturised container, allows the connection of 6 inputs from command devices (buttons, sensors, etc.). Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DIN unit)
  OH/IR-IR RECEIVER MODULE
OH/RI-INPUTS MODULE 1 relay input/output module, 3 digital inputs. Done on miniaturised container, allows the connection of 3 inputs from command devices (buttons, sensors, etc.) and 1 output to an electrical load. Particularly indicated for activations of applications that require the location in loco (example activation of lights with interruption/deviation controls). Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DIN unit).
OH/RP-POWER RELAY MODULE 1 relay output module. Done on miniaturised container, has 1 output for an electrical load. Particularly indicated for activations of loads with high absorption. Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DIN unit).
OH/2RP-EXPANS.POWER RELAY MODULE 2 relay expansion module. Done on miniaturised container, has 1 output for other electrical loads. Is indicated for activations of loads with high absorption. Should always be used in combination with output module OH/RP, which represents the expansion. Is fitted with cable with connector coupling with a connection to the OH/RP module. Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DIN unit).
OH/3RPI-INPUTS/OUTPUTS MODULE 3 relay input/output module, 3 digital inputs. Done on miniaturised container, allows the connection of 3 inputs from command devices (buttons, etc.) and 3 outputs for electrical loads. Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DIN unit) or wall-mounted with the protective cover provided as standard

Probes

Special functions modules

System modules

Zone temperature modules

OH/Z.02 GR-TEMPER.CONTROL MODULE Temperature control area module
OH/Z.02 BB-TEMPER.CONTROL MODULE Temperature control area module
OH/Z.02 SV-TEMPER.CONTROL MODULE Temperature control area module. Allows the temperature control on the area in which it is located. It is possible to select the operating mode (automatic/manual), to modify the ambient temperature or exclude the temperature control for the area concerned. The module can be inserted inside the normal embedded boxes 3 standard modules (BPT plate included in the pack).
OH/FAN-FANCOIL CONTROL MODULE Fan coil basic control module 3 digital outputs for direct management of fan speed and 3 additional digital inputs. Done on miniaturised container it is able to manage a three-speed fan coil unit, by connecting the 3 relays to the fan coil input in order to be able to select one of the fan speeds at whim. It can also, configured by programming software, automatically check the operation of a thermal area fan coil by adjusting the fan speed also through an activation input window contact (automatically turns the fan-coil if a window is open) and by sending the commands to the area's solenoid valves. Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DIN unit) or wall-mounted with the protective cover provided as standard.
OH/FANEVO-FANCOIL CONTROL MODULE Advanced control fan coil. 3 digital outputs for direct management of fan speed and 2 outputs 0-10V analogues to manage the solenoid valves; 2 digital inputs and 1 PTC analogue input. Allows complete management of a three-speed fan coil unit and 2 0-10v of hot and cold solenoid valves (it is therefore able to monitor both the fan speed and the influx of water to the fan coil unit). Through the analogue input and the 2 digital inputs it can also receive data from the temperature sensors or authorisations from window contacts in order to manage its own thermal area. The system will heat up if the temperature is found to be too low and will cool down if too high, independently, without the need for any terminal in its basic functionality and without additional modules. Can be installed, with or without terminal covers, to the wall using the DINguide provided or in containers provided with DINguide (dimensions 6 DINunits).
OH/MT2-INPUTS MODULE Module 2 inputs for PTC or thermocouple temperature probes and 2 0-10V inputs for humidity probes. Allows data to be acquired from 2 analogue inputs for humidity probes type 4-20ma and 2 inputs for specific PTC temperature probes and is therefore capable of detecting temperature and humidity and provide them to the system by bus. Can be installed in boxes fitted with DIN guide and may also be placed in the bottom of an embedded box of 3 or more modules (hindrance 1 DIN unit).